Programing instructions:
Left motor STD roll:
1. Un pack blind and un roll 1/3 of the blind (make sure not to tilt blind as motor may slide out) and install into bracket.
2. Install batteries in remote.
3. Locate P2 button
4. If using multi channel, select channel.
5. Power motor by connecting lead, listen for beep .
6. Within 2-5 seconds of connecting power press P2 + p2
7. Press up on remote
8. Listen for series of beeps
9. Set limits using supplied key.
10. Adjust the down limit by turning the White toggle to the positive, stop turning when you have reached the desired position, if you have passed the desired position press stop reverse the blind by raising the blind until it has well passed the desired limit the toggle to the negative to reduce length . Then repeat step.
11. Adjust the up limit by turning the Red toggle to the positive stop turning when you have reached the desired position, if you have passed the desired position press stop reverse the blind by lowering the blind until it has well passed the desired limit the toggle to the negative to reduce length . Then repeat step.